17-Nov-2014 G2T Programmers Guide Rev-A
19
2.12.2.2. Power-Up Setting
These are global settings that take effect after power-up. They
include:
2.12.2.2.1. Auto Interlock
Two (2) modes of “AUTO INTERLOCK” control are available. With
the Auto-Interlocking feature enabled (On), the unit automatically
disconnects any input connected to the specified output port (or
relay port) before making the new input connection.
With the input Auto-Interlocking feature disabled (Off), the user
must send a disconnect command for the existing cross-point
connection (or relay port connection) prior to connecting any
new input port.